Hangzhou AllTest Biotech CO.,LTD

Hangzhou AllTest Biotech CO.,LTD Your Reliable Rapid Test Partner!

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Fluorescence Immunoassay Test /

mAlb Test Cassette t Use By Fiatest fluorescence Immunoassay Analyzer with CE

Contact Now
Hangzhou AllTest Biotech CO.,LTD
Visit Website
City:hangzhou
Province/State:zhejiang
Country/Region:china
Contact Person:MrsSelina
Contact Now

mAlb Test Cassette t Use By Fiatest fluorescence Immunoassay Analyzer with CE

Ask Latest Price
Video Channel
Brand Name :FIATEST
Model Number :FI-ALB-102
Certification :CE
Place of Origin :China
MOQ :N/A
Price :negotiation
Payment Terms :L/C, T/T
Supply Ability :10 M tests/month
Delivery Time :2-4 Weeks
Packaging Details :10T/25T
Product Name :mAlb Test Cassette t Use By Fiatest fluorescence Immunoassay Analyzer with CE
Principle :Fluorescence Immunoassay
Format :Cassette
Specimen :Urine
Certificate :CE
Reading Time :15 minutes
Pack :10T/25T
Storage Temperature :4-30℃
Shelf Life :2 Years
Cut-Off :20mg/L
Linearity range :5 ~ 300 mg/L , R≥0.990
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

mAlb Test Cassette t Use By Fiatest fluorescence Immunoassay Analyzer with CE

The Microalbumin Test Cassette is based on Fluorescence Immunoassay to measure Microalbumin in Urine as an aid in kidney damage diagnosis.The test result is calculated by Fluorescence Immunoassay Analyzer.

Product Name: MAlb Test Cassette T Use By Fiatest Fluorescence Immunoassay Analyzer With CE
Format: Cassette
Certificate: CE
Pack: 10T/25T
Shelf Life: 2 Years
Linearity Range: 5 ~ 300 Mg/L , R≥0.990
Principle: Fluorescence Immunoassay
Specimen: Urine
Reading Time: 15 Minutes
Storage Temperature: 4-30℃
Cut-Off: 20mg/L

A rapid test for measuring Microalbumin in Urine with the use of Fiatest TM fluorescence Immunoassay Analyzer. For professional in vitro diagnostic use only.

Application:

The Microalbumin Test Cassette (Urine) is based on Fluorescence Immunoassay to measure Microalbumin in Urine.

Description:

The steady expulsion of small quantities of albumin with the urine can be the first sign of kidney damage. In the healthy kidney albumin is usually glomerular filtrated and tubular reabsorbed, so that it is hardly detectable in urine. With a damaged kidney this process is disordered. The expulsion of albumin in the range of 20 - 200 mg/L is characterized as microalbuminuria.1 With this microalbumin test such small concentrations are already securely captured. Especially with diabetics positive results could point to a beginning diabetic nephropathy. Without appropriate therapeutic intervention it will lead for a high percentage of patients to a progression of this complication. The expulsion of albumin increases continuously (= macroalbuminuria) and ends finally after several years in a renal failure, which makes dialysis or a kidney transplant inevitable. In the USA and Europe diabetes is the main cause for terminal kidney failure. A study (DEMAND), accomplished world-wide, shows that approx. 41% of type-2 diabetics exhibit a microalbuminuria. The frequency of microalbuminuria increases with age, blood pressure and diabetes duration, and is the rarer, the better the blood sugar is adjusted. The high prevalence of the illness reveals how important a microalbuminuria annual screening is for diabetics. For type-1 diabetics the first measurements are usually recommended 5 years after initiation of the illness. For type-2 diabetics the screening should start directly with the first outset of the diagnosis, since it is unknown, how long the illness already exists.
The diagnosis of a microalbuminuria is also of special importance, since it can be not only the first sign of a beginning nephropathy but also an indicator for an increased risk for cardiovascular illnesses for type-2 diabetics. An increase of albumin expulsion can be due, to additional factors of influence like physical activity, infections of the urinary tract, high blood pressure, heart insufficiency or surgical interferences (besidesdamages of renal structures).
If the increased albumin expulsion disappears after removal of these factors, it concerns only a transient albuminuria without any pathological reason. Since the albumin expulsion can vary substantially from day to day, at least 2 of 3 urine samples, which were collected over a period of 3-6 months, should show increased albumin values, before a microalbuminuria is diagnosed.

How to use?

Refer to Fiatest TM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be conducted in room temperature.
Allow the test, specimen and/or controls to reach room temperature (15-30°C) prior to testing.
1. Turn on the Analyzer power. Then according to the need, select “Standard test” or “Quick test” mode.
2. Take out the ID card and insert it into the Analyzer port.
3. Pipette 75μL of urine into the buffer tube, mix the specimen and the buffer well.
4. Transfer 75μL diluted sample into the sample well of the test cassette.
5. There are two test modes for Fiatest TM Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode. Please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyzer for details.
“Quick test” mode: After 10 minutes of adding sample,Insert the test cassette into the Analyzer, click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.
“Standard test” mode: Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time, The Analyzer will automatically countdown 10 minutes. After the countdown, the Analyzer will give the result at once.
mAlb Test Cassette t Use By Fiatest fluorescence Immunoassay Analyzer with CE
INTERPRETATION OF RESULTS

Results read by Fiatest TM Fluorescence Immunoassay Analyzer.
The result of tests for Microalbumin is calculated by FluroLitTM Fluorescence Immunoassay
Analyzer and display the result on the screen. For additional information, please refer to the usermanual of Fiatest TM Fluorescence Immunoassay Analyzer.
Linearity range of FluroLitTM Microalbumin Test is 5~300 mg/L.
Reference range:<20 mg/L
Catalogue Number Item Name Sample Test Range KIT size
FI-ALB-102 mAlb Test Cassette Urine 5-300mg/L 10T/25T